Anemometers 〈KDC-S04-05103〉by R.M. YOUNG COMPANY
Sensor for wind direction and speed. Wind speed signal output as sinusoidal frequency. Direction signal output as resistance value from potentiometer.
Most of the parts are made of ABS resin, so they have excellent working resistance.
《Product Features》
- Wind speed resistance is up to 100m/s
- Easy installation & removal (Compatible with 33mm diameter pole)
《Specifications》
Measurement Range | Wind speed: 0~100m/s , Wind direction: 0~355° |
---|---|
Accuracy | ±0.3m/s or 1% of reading (wind speed) ±3° (wind direction) |
Measurement Method | Dispatch method (wind speed)
Potentiometer (wind direction) |
Output Range | 0.098m/s/Hz(wind speed)
0〜10KΩ(wind direction) |
Threshold | 1.0m/s(wind speed), 1.1m/s(wind direction) |
Wind Speed Resistance | 100m/s |
Material | ABS resin, polypropylene |
Power | Unnecessary |
Dimensions | 550(W)×380(H) mm |
Weight | 1.0kg |
Operating Temperature | -50℃ to +50℃ |
Dataloggers compatible to KDC-S04-05103 | KADEC21-KAZE / KADEC21-Me / KADEC21-MeMini / KADEC R-KAZE |
〈Dataloggers compatible to KDC-S04-05103〉 KADEC21-KAZE / KADEC21-Me / KADEC21-MeMini / KADEC R-KAZE
《Specifications for KADEC21-KAZE》
Wind direction and Wind speed |
Devices | Wind direction and anemometer (Standard, breeze, three cups anemometer) |
---|---|---|
Measurement Range | Wind direction: 0~360° (16 directions) Wind speed:0~90m/s |
|
Accuracy | Wind direction: within ±0.2% Wind speed:±0.2m/s |
|
Measurement Accuracy | Wind direction: 1° (16 directions) Wind speed:0.1m/s |
|
Recording Elements (11 elements) |
Average wind speed/direction Instantaneous maximum wind speed, wind direction and threshold Moving average maximum wind speed, wind direction and threshold Instantaneous maximum wind speed, wind direction Wind speed standard deviation |
|
Measurement Interval | 1sec ~ 6min (Instantaneous maximum wind speed, wind direction only) 10min, 1hr (11 elements recording available) |
|
Battery Life | 10 months (10 min interval recording, 5 elements recording, 2 unit battery option setting) | |
Dimensions | 175(W)×125(D)×75(H)mm | |
Weight | 0.8kg |
《Specifications for KADEC21-Me》
Wind direction and wind speed | Measurement Range | Wind direction: 0~360° Wind speed: 0~90m/s |
---|---|---|
Accuracy | Wind direction: ±0.2% Wind speed: ±0.2m/s |
|
Resolution | Wind direction: 1° Wind speed: 0.1m/s |
|
Recording Element | Average of wind direction and speed 10 minutes before recording starts Between intervals: Instantaneous maximum wind speed, wind direction and threshold |
|
Temperature | Measurement Range | −200~+200℃ |
Measurement Method | Platinum resistance thermometer | |
Resolution | 0.01℃ | |
Recording Value | Instantaneous value taken during interval | |
Humidity | Measurement Range | 0~100% |
Accuracy | 0.1% | |
Resolution | 0.1% | |
Rainfall | Measurement Range | 0~5,000mm |
Input Signal | No-voltage contact | |
Resolution | 0.5mm | |
Recording Value | Integrated value taken during interval | |
Solar Irradiance | Measurement Range | 0~2kw/㎡ |
Measurement Method | Temperature sensor | |
Measurement | 0.01kw/㎡ | |
Recording Value | Integrated value taken during interval | |
Sunshine Duration | Sunshine Threshold | 120w/㎡ |
Measurement Method | Bimetal contact signal | |
Resolution | 1min | |
Recording Value | Sunshine duration during interval (min) | |
Barometric pressure | Measurement Range | 600~1100hPa |
Measurement Method | Diode gauge type | |
Resolution | 0.1hPa | |
Voltage(5ch) | Input Channels | 5ch |
Measurement Range | 0~±2V | |
Resolution | 0.1mV | |
Measurement Interval | 10min~24 hours | |
Battery Life |
4.9 months in 10min interval (11 elements recording) 10 months in 60min interval (11 elements recording) |
|
Dimensions | 240(W)×160(D)×91(H)mm | |
Weight | 1.5kg |
《Specifications for KADEC21-MeMini》
Wind direction and wind speed | Measurement Range | Wind direction: 0~360° Wind speed: 0~90m/s |
---|---|---|
Accuracy | Wind direction: ±0.2% Wind speed: ±0.2m/s |
|
Resolution | Wind direction: 1° Wind speed: 0.1m/s |
|
Recording Element | Average of wind direction and speed 10 minutes before recording starts Between intervals: Instantaneous maximum wind speed, wind direction and threshold |
|
Temperature | Measurement Range | −200~+200℃ |
Measurement Method | Platinum resistance thermometer(NJPT100Ω/0°4 wire-system) | |
Resolution | 0.01℃ | |
Humidity | Measurement Range | 0〜100% |
Accuracy | 0.1% | |
Resolution | 0.1% | |
Recording value | Instantaneous value during interval | |
Depth of Snow | Measurement Range | 0~10m |
Accuracy | ±1cm | |
Resolution | 1mm | |
Recording value | Instantaneous value during interval | |
Rainfall | Measurement Range | 0~5,000mm |
Input Signal | No-voltage contact | |
Recording Value | Cumulative value during interval | |
Recording intervals | 1~30min, 1hr, 2 hours, 3 hours | |
Battery Life | 8.8 months in 10min interval 6.8 months in 1hr interval of snow depth |
|
Dimensions | 240(W)×160(D)×91(H)mm | |
Weight | 1.3kg |
《Specifications for KADEC R-KAZE》
Input | Input Channels | 4 | |
---|---|---|---|
Voltage | Measurement Range | 0~±2V | |
Resolution | 0.1mV | ||
Recording Value | Instantaneous value during interval | ||
Accuracy | ±0.1% FS | ||
Current | Measurement Range | 0~±20mA 100Ω load resistance built-in | |
Resolution | 0.1uA | ||
Recording Value | Instantaneous value during interval | ||
Accuracy | ±0.15% of FS | ||
Measurement Intervals | 1,2,3,4,5,6,7,12,15,20,30/ sec | ||
1,2,3,4,5,6,7,12,15,20,30/ min | |||
1,2,3,4,6,8,12,24/ hour | |||
Recording data | Storage Capacity | 97,280 elements | |
Storage Media | Non-volatile memory | ||
Memo function | Number of memo: 6 | ||
Memo Capacity: 16 characters | |||
Character: Alphabet, Katakana, Symbol | |||
Storage Method | Memory scroll method | ||
Recording Media | Card Type | SD Card | |
FAT Fomat | FAT、FAT32 | ||
Capacity | 32GB or below | ||
Format | CSV format | ||
Data transfer | Manual backup or automatic data transfer | ||
Communication function | Communication method | RS-232C | |
For maintenance and external device connection | |||
Display | LCD 16 digits, 2 lines (operating temperature: -20~+80 degrees) | ||
※When temperature is below -10℃, response of display slows down and fades out slightly. | |||
※After 90 seconds of idle time, display automatically turns off | |||
Operation Keys | 3 Push Buttons (UP/Down/Enter) | ||
Slide switch (Recording start / stop) | |||
Standard Function | Pre-Timer | Turning ON/OFF of the external devices before start of recording | |
Option: OFF, 1~30 sec, 1~59 min | |||
After Timer | Recording starts after the specified date and time | ||
(Default setting is disabled) | |||
10 Steps Indicator on the LCD Screen | 10 steps indicator on the LCD screen | ||
※Resets when the battery is replaced. | |||
Battery Indicator | Power Consumption | 20mA (excluding the time when data are written on SD card.) | |
50uA in standby mode | |||
Power Source | Exclusive battery or 2 CR123A | ||
External power DV12V (Maximum DC 24V) | |||
Data Storage Power Supply | CR123A×1 | ||
Operating System | I-TRON(Real time OS) | ||
Working Environment | -25℃ to 80℃ |