Anemometers 〈KDC-S04-05103〉by R.M. YOUNG COMPANY

Sensor for wind direction and speed. Wind speed signal output as sinusoidal frequency. Direction signal output as resistance value from potentiometer.

Most of the parts are made of ABS resin, so they have excellent working resistance.

Anemometer 《KDC-S04-05103》
 

Product Features

  • Wind speed resistance is up to 100m/s
  • Easy installation & removal (Compatible with 33mm diameter pole)

 

Specifications

Measurement Range Wind speed: 0~100m/s , Wind direction: 0~355°
Accuracy ±0.3m/s or 1% of reading (wind speed)
±3° (wind direction)
Measurement Method Dispatch method (wind speed)

Potentiometer (wind direction)

Output Range 0.098m/s/Hz(wind speed)

0〜10KΩ(wind direction)

Threshold 1.0m/s(wind speed), 1.1m/s(wind direction)
Wind Speed Resistance 100m/s
Material ABS resin, polypropylene
Power Unnecessary
Dimensions 550(W)×380(H) mm
Weight 1.0kg
Operating Temperature -50℃ to +50℃
Dataloggers compatible to KDC-S04-05103 KADEC21-KAZE / KADEC21-Me / KADEC21-MeMini / KADEC R-KAZE

 

〈Dataloggers compatible to KDC-S04-05103〉 KADEC21-KAZE / KADEC21-Me / KADEC21-MeMini / KADEC R-KAZE

 

 

Specifications for KADEC21-KAZE

Wind direction and
Wind speed
Devices Wind direction and anemometer (Standard, breeze, three cups anemometer)
Measurement Range Wind direction: 0~360° (16 directions)
Wind speed:0~90m/s
Accuracy Wind direction: within ±0.2%
Wind speed:±0.2m/s
Measurement Accuracy Wind direction: 1° (16 directions)
Wind speed:0.1m/s
Recording Elements
(11 elements)
Average wind speed/direction
Instantaneous maximum wind speed, wind direction and threshold
Moving average maximum wind speed, wind direction and threshold
Instantaneous maximum wind speed, wind direction
Wind speed standard deviation
Measurement Interval 1sec ~ 6min (Instantaneous maximum wind speed, wind direction only)
10min, 1hr (11 elements recording available)
Battery Life 10 months (10 min interval recording, 5 elements recording, 2 unit battery option setting)
Dimensions 175(W)×125(D)×75(H)mm
Weight 0.8kg

 

 

Specifications for KADEC21-Me

Wind direction and wind speed Measurement Range Wind direction: 0~360°
Wind speed: 0~90m/s
Accuracy Wind direction: ±0.2%
Wind speed: ±0.2m/s
Resolution Wind direction: 1°
Wind speed: 0.1m/s
Recording Element Average of wind direction and speed 10 minutes before recording starts
Between intervals: Instantaneous maximum wind speed, wind direction and threshold
Temperature Measurement Range −200~+200℃
Measurement Method Platinum resistance thermometer
Resolution 0.01℃
Recording Value Instantaneous value taken during interval
Humidity Measurement Range 0~100%
Accuracy 0.1%
Resolution 0.1%
Rainfall Measurement Range 0~5,000mm
Input Signal No-voltage contact
Resolution 0.5mm
Recording Value Integrated value taken during interval
Solar Irradiance Measurement Range 0~2kw/㎡
Measurement Method Temperature sensor
Measurement 0.01kw/㎡
Recording Value Integrated value taken during interval
Sunshine Duration Sunshine Threshold 120w/㎡
Measurement Method Bimetal contact signal
Resolution 1min
Recording Value Sunshine duration during interval (min)
Barometric pressure Measurement Range 600~1100hPa
Measurement Method Diode gauge type
Resolution 0.1hPa
Voltage(5ch) Input Channels 5ch
Measurement Range 0~±2V
Resolution 0.1mV
Measurement Interval 10min~24 hours
 Battery Life
4.9 months in 10min interval (11 elements recording)
10 months in 60min interval (11 elements recording)
Dimensions 240(W)×160(D)×91(H)mm
Weight 1.5kg

 

Specifications for KADEC21-MeMini

Wind direction and wind speed Measurement Range Wind direction: 0~360°
Wind speed: 0~90m/s
Accuracy Wind direction: ±0.2%
Wind speed: ±0.2m/s
Resolution Wind direction: 1°
Wind speed: 0.1m/s
Recording Element Average of wind direction and speed 10 minutes before recording starts
Between intervals: Instantaneous maximum wind speed, wind direction and threshold
Temperature Measurement Range −200~+200℃
Measurement Method Platinum resistance thermometer(NJPT100Ω/0°4 wire-system)
Resolution 0.01℃
Humidity Measurement Range 0〜100%
Accuracy 0.1%
Resolution 0.1%
Recording value Instantaneous value during interval
Depth of Snow Measurement Range 0~10m
Accuracy ±1cm
Resolution 1mm
Recording value Instantaneous value during interval
Rainfall Measurement Range 0~5,000mm
Input Signal No-voltage contact
Recording Value Cumulative value during interval
Recording intervals 1~30min, 1hr, 2 hours, 3 hours
Battery Life 8.8 months in 10min interval
6.8 months in 1hr interval of snow depth
Dimensions 240(W)×160(D)×91(H)mm
Weight 1.3kg

 

 

Specifications for KADEC R-KAZE

Input Input Channels 4
Voltage Measurement Range 0~±2V
Resolution 0.1mV
Recording Value Instantaneous value during interval
Accuracy ±0.1% FS
Current Measurement Range 0~±20mA 100Ω load resistance built-in
Resolution 0.1uA
Recording Value Instantaneous value during interval
Accuracy ±0.15% of FS
Measurement Intervals 1,2,3,4,5,6,7,12,15,20,30/ sec
1,2,3,4,5,6,7,12,15,20,30/ min
1,2,3,4,6,8,12,24/ hour
Recording data Storage Capacity 97,280 elements
Storage Media Non-volatile memory
Memo function Number of memo: 6
Memo Capacity: 16 characters
Character: Alphabet, Katakana, Symbol
Storage Method Memory scroll method
Recording Media Card Type SD Card
FAT Fomat FAT、FAT32
Capacity 32GB or below
Format CSV format
Data transfer Manual backup or automatic data transfer
Communication function Communication method RS-232C
For maintenance and external device connection
Display LCD 16 digits, 2 lines (operating temperature: -20~+80 degrees)
※When temperature is below -10℃, response of display slows down and fades out slightly.
※After 90 seconds of idle time, display automatically turns off
Operation Keys 3 Push Buttons (UP/Down/Enter)
Slide switch (Recording start / stop)
Standard Function Pre-Timer Turning ON/OFF of the external devices before start of recording
Option: OFF, 1~30 sec, 1~59 min
After Timer Recording starts after the specified date and time
(Default setting is disabled)
10 Steps Indicator on the LCD Screen 10 steps indicator on the LCD screen
※Resets when the battery is replaced.
Battery Indicator Power Consumption 20mA (excluding the time when data are written on SD card.)
50uA in standby mode
Power Source Exclusive battery or 2 CR123A
External power DV12V (Maximum DC 24V)
Data Storage Power Supply CR123A×1
Operating System I-TRON(Real time OS)
Working Environment -25℃ to 80℃

 

 

MENU