Tipping Bucket Type Rain Gauge〈KDC-S13-RT-5E〉by Ikeda Keiki
A tipping bucket rain gauge records cumulative rainfall. An orifice with 200mm diameter catches rainwater and pours it into a water bucket. When the water bucket catches rainwater equivalent to 0.5mm or 15.7cc, the bucket is tipped, and a pulse signal is sent to the recorder.
※Japan Meteorological Agency certification available

- Japan Meteorological Agency certification available
- Made of stainless steel, to resist rust
- Heater option model available for cold weather environment.
《Specifications》
| Detection Method | Tipping bucket type |
|---|---|
| Orifice Diameter | 200mm±0.6mm, tips at 0.5mm increments |
| Accuracy | Within 0.5mm accuracy (for rainfall of 20mm or less) Within 3% (for rainfall of 20mm or more) |
| Reed switch | 10VA:DC100V, 0.4A(MAX) Contact time: 0.1-0.18 sec |
| Dataloggers compatible to KDC-S13-RT-5E | KADEC21-MIZU/KADEC21-Me/KADEC21-MeMini/TAMAPod LLUVIA-2, TAMAPod PULSO-2 |
| Dimensions | Φ218×450(H)mm |
| Weight | 4.5kg |
〈Dataloggers compatible to KDC-S13-RT-5E〉KADEC21-MIZU / KADEC21-Me / KADEC21-MeMini

《Specifications for KADEC21-MIZU》
| Wind direction and wind speed | Sensor to be connected | Semiconductor gauge type water level sensor KDC-S10-TM/N |
|---|---|---|
| Measurement Range | 1.75、10、20、50、100m(Select at the time of purchase) | |
| Accuracy | ±0.1 of FS | |
| Measurement Accuracy | 1mm | |
| Functions | Water level offset, averaging of waves | |
| Rainfall Measurement | Increments of : Tipping Bucket Type Rain Gauge | 0.5mm、1mm (Select at the time of purchase) |
| Recorded Data | Cumulative rainfall between intervals | |
| Measurement Interval | From 10 min to 24 hours, external trigger signal (Setting is optional.) | |
| Battery Life | 32 months (10min interval measurement) 89 months (60min interval measurement) |
|
| Dimensions | 175(W)×125(D)×75(H)mm | |
| Weight | 0.8kg(excluding protrusions) | |
《Specifications for KADEC21-Me》
| Wind direction and wind speed | Measurement Range | Wind direction: 0~360° Wind speed: 0~90m/s |
|---|---|---|
| Accuracy | Wind direction: ±0.2% Wind speed: ±0.2m/s |
|
| Resolution | Wind direction: 1° Wind speed: 0.1m/s |
|
| Recording Element | Average of wind direction and speed 10 minutes before recording starts Between intervals: Instantaneous maximum wind speed, wind direction and threshold |
|
| Temperature | Measurement Range | −200~+200℃ |
| Measurement Method | Platinum resistance thermometer | |
| Resolution | 0.01℃ | |
| Humidity | Measurement Range | 0~100% |
| Accuracy | 0.1% | |
| Resolution | 0.1% | |
| Rainfall | Measurement Range | 0~5000mm |
| Input Signal | No-voltage contact | |
| Resolution | 0.5mm | |
| Recording Value | Integrated value taken during interval | |
| Solar Irradiance | Measurement Range | 0~2kw/㎡ |
| Measurement Method | Temperature sensor | |
| Measurement | 0.01kw/㎡ | |
| Recording Value | Integrated value taken during interval | |
| Sunshine Duration | Sunshine Threshold | 120w/m2 |
| Measurement Method | Bimetal contact signal | |
| Resolution | 1min | |
| Recording Value | Sunshine duration during interval (min) | |
| Barometric pressure | Measurement Range | 600~1100hPa |
| Measurement Method | Diode gauge type | |
| Resolution | 0.1hPa | |
| Voltage(5ch) | Input Channels | 5ch |
| Measurement Range | 0~±2V | |
| Resolution | 0.1mV | |
| Measurement Interval | 10 min~24 hours | |
| Battery Life | 4.9 months at 10-min. interval (when recording 11 elements) 10 months at 60-min. interval (when recording 11 elements) |
|
| Dimensions | 240(W)×160(D)×91(H)mm | |
| Weight | 1.5kg | |
《Specifications for KADEC21-MeMini》
| Wind direction and wind speed | Measurement Range | Wind direction: 0~360° Wind speed: 0~90m/s |
|---|---|---|
| Accuracy | Wind direction: ±0.2% Wind speed: ±0.2m/s |
|
| Measurement Accuracy | Wind direction: 1° Wind speed: 0.1m/s |
|
| Recording Element | Average of wind direction and speed 10 minutes before recording starts Between intervals: Instantaneous maximum wind speed, wind direction and threshold |
|
| Temperature | Measurement Range | −200~+200℃ |
| Measurement Method | Platinum resistance thermometer(NJPT100Ω/0°4 wire-system) | |
| Resolution | 0.01℃ | |
| Recording Value | Instantaneous value during interval | |
| Humidity | Measurement Range | 0〜100% |
| Accuracy | 0.1% | |
| Resolution | 0.1% | |
| Recording Value | Instantaneous value during interval | |
| Depth of Snow | Measurement Range | 0~10m |
| Accuracy | ±1cm | |
| Resolution | 1mm | |
| Recording value | Instantaneous value during interval | |
| Rainfall | Resolution | 0~5000mm |
| Input Signal | No-voltage contact | |
| Recording Value | Cumulative value during interval | |
| Recording intervals | 1~30min, 1hr, 2 hours, 3 hours | |
| Battery Life | 8.8 months in 10min interval 6.8 months in 1hr interval of snow depth |
|
| Dimensions | 240(W)×160(D)×91(H)mm | |
| Weight | 1.3kg | |